The common malfunction analysis of laser cutting machine
by:Transon
2020-10-27
Common fault of a laser cutting machine, laser light 1, press operation panel test observation ammeter state: 1) no current: check whether the laser power supply is switched on, the high tension line is loose or fall off, line is loose;
(2) there are current: check whether the lens is broken, the light path is serious deviation;
2, check the water circulation system is normal: (1) no drainage systems: check whether the water pump is damaged or no electricity;
(2) water: check whether the water inlet and outlet can reverse or water pipe broke 3, some directly, can self-check, sending data is 1 led and reset is not straight, check whether the sensor is stained with dust, poor contact or damaged;
2, check whether flexible conduction band cable poor contact or damage;
3, check whether the ground contact is reliable, or whether the high tension line;
4, electrical line contact undesirable.
Three, miss cut 1, initialization is not correct, has to send data;
2, operation order;
3, electrostatic interference