Enclosed Type

Laser cutting machine flame welding to abate

by:Transon     2020-10-28
The cause of the laser cutting machine flame welding to abate
1, the main optical path laser offset the solution: adjust the light path full and half the diaphragm, the paper checks and circular spot 2, focus lens damage or pollution treatment method: replace or focus lens cleaning and protection of the lens. 3, laser without the gas nozzle from focusing on the following at the center of the output the solution: adjust the reflective membrane, 45 degrees to 4, laser laser output from the center of the gas mouth cavity of diaphragm of damage or pollution of the solution: replacement or cleaning cavity reflection film. 5, brake light not bounce off the solution: check and add the lubricating oil on the brake light fittings, fittings machinery can smoothly in June and the service life of the xenon lamp in the solution: check and clean the old lamp or replace new xenon lamp. 7 or long-term didn't replace the cooling water, cooling water pollution the solution: replacement of cooling water and clean the filter uv glass tube and xenon lamp of 8, focusing mirror from the solution: large amount of focus of the adjustment of coke to focus the closest position ( But there can be no splash content) 9, shielding gas too large the solution: adjust the flow of gas shielding gas