Laser cutting machine processing size is error or motion error check grounding is normal: the whole machine and computer equipment and computer good grounding. Line is normal, replace the signal lines. Computer operating system failure or infection: reinstall the operating system or antivirus. Computer operation is normal, replace or deal with the computer. Power supply is not stable or interfering signal: adding stabilizer or eliminate interference signal. Application software is normal: to install the software and motion control card driver software. Processing parameters are set correctly ( Such as layout, etc. ) : to set up the corresponding parameter processing programming is normal: check the writing process, changes to make it normal.