The cause of laser cutting machine laser tube is not out of light: (
1)
Water level switch is broken.
(
2)
The high tension line break.
(
3)
Laser tube rupture or burn out.
(
4)
Laser power supply is broken.
(
5)
Without water, including water pipe plug and the water pump does not work.
(
6)
Soil conservation convenient break or contact is not good.
(
7)
Laser power supply voltage to less than 220 v.
(
8)
No signal into the laser power.
(
9)
Online biaxial card is broken.